CSS-14091 coolant supply system supplies a water glycol mix at 8-20 GPM and 100-190F to radiators and other thermal transfer devices. Test data is collected and used to establish optimum pressures, temperatures, and flow rates. This system was designed to supply a water glycol mix at the operating temperatures, flows and pressures found in a diesel engine cooling system. It eliminated the need to operate a large diesel engine while reducing the time required to set up and test radiators and other components. The compact size and mobility allowed the customer to eliminate noise and congestion in their test area.
Prior to building this system IFS worked with the contractor to establish the range of flow rates, temperatures and pressures required for testing.
IFS has 25 years of experience building turnkey systems for: